Models
1532E2
1932E2
2032E2
2632E2
2646E2
3246E2
3120855
May 10, 2006
SERVICE & MAINTENANCE
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - May 10, 2006

Models1532E21932E22032E22632E22646E23246E23120855May 10, 2006SERVICE & MAINTENANCE

Strany 2

SECTION 1 - SPECIFICATIONS1-4 – JLG Sizzor– 31208551.6 SERIAL NUMBER LOCATIONSFor machine identification, a serial number plate is affixedto the machi

Strany 3 - PRECAUTIONS

SECTION 1 - SPECIFICATIONS3120855 – JLG Sizzor – 1-51.9 PRESSURE SETTINGSPressure Settings for Non Proportional Control MachinesMain Relief Max - 221

Strany 4 - REVISON LOG

SECTION 1 - SPECIFICATIONS1-6 – JLG Sizzor– 3120855Figure 1-2. Torque Chart.

Strany 5 - TABLE OF CONTENTS

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-1SECTION 2. PROCEDURES2.1 GENERALThis section provides information necessary to performmaintenance on

Strany 6 - (Continued)

SECTION 2 - PROCEDURES2-2 – JLG Sizzor – 3120855Pressure-Fit PartsWhen assembling pressure-fit parts, use an anti-seize ormolybdenum disulfide base co

Strany 7 - SECTION 1. SPECIFICATIONS

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-33. Cloudy oils indicate a high moisture content whichpermits organic growth, resulting in oxidation or

Strany 8 - 1-2 – JLG Sizzor– 3120855

SECTION 2 - PROCEDURES2-4 – JLG Sizzor – 3120855released, the spool automatically returns to neutral, pro-hibiting any flow through the circuit.Relief

Strany 9 - 3120855 – JLG Sizzor – 1-3

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-5Cylinders w/Single Holding Valves - Lift CylinderOPERATE ALL FUNCTIONS FROM GROUND CONTROL STATIONONLY

Strany 10 - 1.8 CYLINDER SPECIFICATIONS

SECTION 2 - PROCEDURES2-6 – JLG Sizzor – 31208554. Place the cylinder barrel into a suitable holding fix-ture5. If applicable, using a suitable spanne

Strany 11 - 3120855 – JLG Sizzor – 1-5

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-77. Using this as a handle, pull out the piston rod andextend until the piston bottoms out on the head8

Strany 13 - SECTION 2. PROCEDURES

SECTION 2 - PROCEDURES2-8 – JLG Sizzor – 31208551. Using a special tool, pictured in the following illustra-tion, install a new rod seal into the appl

Strany 14 - 2-2 – JLG Sizzor – 3120855

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-92.11 BRAKE CYLINDER REPAIRDisassemblyDISASSEMBLY OF THE CYLINDER SHOULD BE PERFORMED ONA CLEAN WORK SU

Strany 15 - 3120855 – JLG Sizzor – 2-3

SECTION 2 - PROCEDURES2-10 – JLG Sizzor – 3120855Cleaning and Inspection1. Clean all parts thoroughly in an approved cleaningsolvent.2. Inspect the cy

Strany 16 - 2-4 – JLG Sizzor – 3120855

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-11EXTREME CARE SHOULD BE TAKEN WHEN REMOVING THE CYL-INDER ROD, GUIDE, AND PISTON. AVOID PULLING THE RO

Strany 17 - 3120855 – JLG Sizzor – 2-5

SECTION 2 - PROCEDURES2-12 – JLG Sizzor – 31208558. Inspect seal and o-ring grooves in guide for burrsand sharp edges. Dress applicable surfaces as ne

Strany 18 - SECTION 2 - PROCEDURES

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-134. Slowly back off the nut, counting the number ofturns, until the circuit is closed again5. Divide t

Strany 19 - Assembly

SECTION 2 - PROCEDURES2-14 – JLG Sizzor – 31208552.14 PRESSURE SETTING PROCEDURES NOTE: Make all pressure adjustments with motor operatingand hydrauli

Strany 20

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-15Main Relief Pressure Switch for Non Proportional Control Machines1. Install a pressure gauge at gauge

Strany 21 - Disassembly

SECTION 2 - PROCEDURES2-16 – JLG Sizzor – 3120855 Figure 2-12. Control Valve Components (3246E2 w/Proportional Control)

Strany 22 - 2.12 STEER CYLINDER REPAIR

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-17WELDERTERMINALCONNECTORFIREEXTINGUISHERFigure 2-13. Quick Welder™ Installation

Strany 23

INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONS3120855 – JLG Sizzor – aSECTION A. INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONSA.A GENERALThis section

Strany 24 - Manual Adjustment

SECTION 2 - PROCEDURES2-18 – JLG Sizzor – 31208552.15 DRIVE MOTOR (SAUER DANFOSS)Dismantling1. Place motor in proper holding device that allowsaccess

Strany 25 - Voltmeter Adjustment

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-19AssemblyNOTE: Before assembly, inspect all parts and replace if nec-essary.Before assembly, lubricate

Strany 26 - 2-14 – JLG Sizzor – 3120855

SECTION 2 - PROCEDURES2-20 – JLG Sizzor – 31208554. Screw in the 8 socket head cap screws. Using aTorque wrench, tighten to 80 in lb (8 Nm).5. After t

Strany 27 - 3120855 – JLG Sizzor – 2-15

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-21.4. Remove end cover assembly (2) and seal ring (4).Discard seal ring.NOTE: Refer to the appropriate

Strany 28

SECTION 2 - PROCEDURES2-22 – JLG Sizzor – 31208555. If the end cover (2) is equipped with shuttle valvecomponents, remove the two previously loosene

Strany 29

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-236. Thoroughly wash end cover (2) in proper solventand blow dry. Be sure the end cover valve apertures

Strany 30 - Dismantling

SECTION 2 - PROCEDURES2-24 – JLG Sizzor – 312085510. Remove rotor set (8) and warplane (9), together toretain the rotor set in its assembled form, mai

Strany 31 - 2.16 DRIVE MOTOR (REXROTH)

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-2513. Remove thrust bearing (11) from top of couplingshaft (12). Inspect for wear, brinelling, corrosio

Strany 32 - Disassembly and inspection

SECTION 2 - PROCEDURES2-26 – JLG Sizzor – 312085519. Remove housing (18) from vise, invert it and removeand discard seal (20). A blind hole bearing or

Strany 33

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-27NOTE: The depth or location of bearing/bushing (13) in rela-tion to the housing wear plate surface an

Strany 34

INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONSb – JLG Sizzor – 3120855REVISON LOGOriginal Issue - June 1998Revised - March 5, 1999 (Added 3246E2)Revise

Strany 35

SECTION 2 - PROCEDURES2-28 – JLG Sizzor – 3120855NOTE: Bearing mandrel must be pressed against the let-tered end of bearing shell. Take care that the

Strany 36

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-29The Torqlink™ dirt and water seal (20) must be pressed inuntil its’ flange is flush against the housi

Strany 37

SECTION 2 - PROCEDURES2-30 – JLG Sizzor – 31208557. Apply masking tape around splines or keyway onshaft (12) to prevent damage to seal. 8. Be sure tha

Strany 38

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-3110. Install drive link (10) the long splined end down intothe coupling shaft (12) and engage the driv

Strany 39

SECTION 2 - PROCEDURES2-32 – JLG Sizzor – 312085515. Assemble the manifold (7) over the alignment studsand drive link (10) and onto the rotor set. Be

Strany 40

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-33NOTE: If the end cover has a valve (24) or has five boltholes, use the line you previously scribed o

Strany 41

SECTION 2 - PROCEDURES2-34 – JLG Sizzor – 3120855lbs.(61-75 N m) if cover is so equipped.One Piece Stator ConstructionA disassembled rotor (8A) stator

Strany 42

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-35the seventh or full complement of seven vanes.Assemble the seven vanes using minimum force.Remove the

Strany 43

SECTION 2 - PROCEDURES2-36 – JLG Sizzor – 3120855INTRODUCTIONThe JLG designed SMART System™ is a 24 Volt multiplexmotor control unit installed on the

Strany 44

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-371: STARTUP (2/1)At this point, the analyzer will display the current fault, ifany are present. You ma

Strany 45 - 3120855 – JLG Sizzor – 2-33

3120855 – JLG Sizzor – i TABLE OF CONTENTSTABLE OF CONTENTSSUBJECT - SECTION, PARAGRAPH PAGE NO.SECTION A - INTRODUCTION - MAINTENANCE

Strany 46 - One Piece Stator Construction

SECTION 2 - PROCEDURES2-38 – JLG Sizzor – 3120855NOTE: Refer to the appropriate Machine Personality Set-tings Table, and the Machine Setup Table in th

Strany 47 - 3120855 – JLG Sizzor – 2-35

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-39Figure 2-17. Organizational Chart

Strany 48 - Using the Analyzer:

SECTION 2 - PROCEDURES2-40 – JLG Sizzor – 31208552.21 MACHINE PERSONALITY SETTINGS Table 2-4. Machine Personality SettingsPERSONALITY MIN MAXDRIVE-AC

Strany 49 - Analyzer:

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-412.22 MACHINE MODEL DEFAULT SETTINGS Table 2-5. Machine Model Default Settings Chart Adjustment 3246E

Strany 50

SECTION 2 - PROCEDURES2-42 – JLG Sizzor – 31208552.23 MACHINE CONFIGURATION INFORMATIONNOTE: The following information is to be used when workingwith

Strany 51

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-435(FUNCTION CUTOUT)01No function cutout installed.Overload switch for French, Japanese machines. — Cut

Strany 52

SECTION 2 - PROCEDURES2-44 – JLG Sizzor – 31208552.24 JLG SMART SYSTEM™ HELP MESSAGES AND FLASH CODES Table 2-7. Help MessagesNO FLASH CODE IS I

Strany 53

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-45Table 2-8. JLG SMART System™ Flash Codes & Help MessagesCode Description2-1 - Indicates problems

Strany 54 - INFORMATION

SECTION 2 - PROCEDURES2-46 – JLG Sizzor – 31208553-3 - Indicates that a contactor coil is short-circuit SHORT-CIRCUIT LINE CONTACTOR COIL - The line c

Strany 55

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-472.25 ANALYZER MENU STRUCTURE In the following structure descriptions, an intended item isselected by

Strany 56 - MESSAGES AND FLASH CODES

ii – JLG Sizzor – 3120855TABLE OF CONTENTS (Continued) LIST OF FIGURESFIGURE NO. TITLE PAGE NO.1-1. Serial Number Location. . . . . . . . . . .

Strany 57

SECTION 2 - PROCEDURES2-48 – JLG Sizzor – 3120855SYSTEMSBATTERYTEMPERATUREPUMP VOLTPUMP AMPELEVATIONDisplays measured battery voltageNOTE: Only accura

Strany 58

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-49DATALOGONDRIVELIFTDECKPUMPRENTALERASE RENTAL(YES:ENTER,NO ESC)MAX. TEMPMIN. TEMPMAX BATTERYDisplays t

Strany 59 - 2.25 ANALYZER MENU STRUCTURE

SECTION 2 - PROCEDURES2-50 – JLG Sizzor – 3120855ACCESS LEVEL CODEDisplays the current access levelLevel 3 - Personalities cannot be changedLevel 2 -

Strany 60

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-51DECKACCELDECELCREEPMAX OUTMAX INDisplays/adjusts deck accelerationDisplays/adjusts deck decelerationD

Strany 61

SECTION 2 - PROCEDURES2-52 – JLG Sizzor – 3120855MACHINE SETUPCALIBRATIONSMODEL NUMBERTILT SWITCHPOWER DECKDECK EXT. LIMITFUNCTION CUTOUTGROUND ALARMD

Strany 62

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-532.26 PREVENTIVE MAINTENANCE AND INSPECTION SCHEDULEThe preventive maintenance and inspection checks a

Strany 63

SECTION 2 - PROCEDURES2-54 – JLG Sizzor – 3120855Table 2-10. Preventive Maintenance and Inspection ScheduleDaily Weekly Monthly 3 Month 6 Month 1 Year

Strany 64

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-1SECTION 3. TROUBLESHOOTING3.1 GENERALThis section contains troubleshooting information to beused

Strany 65 - INSPECTION SCHEDULE

SECTION 3 - TROUBLESHOOTING3-2 – JLG Sizzor – 3120855Table 3-1. Electricl Troubleshooting ChartTROUBLE PROBABLE CAUSE REMEDYAll machine functions do n

Strany 66

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-3Table 3-2. Hydraulic System Troubleshooting ChartTROUBLE PROBABLE CAUSE REMEDYHydraulic pump nois

Strany 67 - SECTION 3. TROUBLESHOOTING

SECTION 1 - SPECIFICATIONS3120855 – JLG Sizzor – 1-1SECTION 1. SPECIFICATIONS1.1 CAPACITIESHydraulic Oil Tank1932E211.4 liters at full mark on tank9.

Strany 68 - SECTION 3 - TROUBLESHOOTING

SECTION 3 - TROUBLESHOOTING3-4 – JLG Sizzor – 3120855Figure 3-1. Electrical Schematic - Non Proportional Control (Sheet 1 of 2)

Strany 69

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-51870117 CFigure 3-2. Electrical Schematic - Non Proportional Control (Sheet 2 of 2)

Strany 70

SECTION 3 - TROUBLESHOOTING3-6 – JLG Sizzor – 3120855 U3JLG SMART SYSTEMMICROPROCESSORFigure 3-3. Electrical

Strany 71

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-7U3JLG SMART SYSTEMMICROPROCESSOR1870107BFigure 3-4. Electrical Schematic - Proportional Control

Strany 72 - MICROPROCESSOR

SECTION 3 - TROUBLESHOOTING3-8 – JLG Sizzor – 3120855NOTE: CASE DRAIN IS ONLY FOR 3246E2;THEREFORE, 2646E2 LIFT CYL HOSES MUSTBE CONNECTED DIRECTLY TO

Strany 73 - 1870107B

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-9 2792399 BFigure 3-6. Hydraulic Schematic - 3246E2 Proprtional Control

Strany 74 - 1282851 I

SECTION 3 - TROUBLESHOOTING3-10 – JLG Sizzor – 3120855Figure 3-7. Harness and Cable Assembly - Non Proportional Control (Sheet 1 of 2)

Strany 75 - 2792399 B

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-11Figure 3-8. Harness and Cable Assembly - Non Proportional Control (Sheet 2 of 2)

Strany 76

SECTION 3 - TROUBLESHOOTING3-12 – JLG Sizzor – 3120855This page left blank intentionally.

Strany 78

SECTION 1 - SPECIFICATIONS1-2 – JLG Sizzor– 3120855GradeabilityAll Models - 25%Inside Turning Radius1932E2 - 0.5 m2032E2/2632E2 - 1m2646E2 - 1 m3246E2

Strany 79

JLG Worldwide LocationsCorporate OfficeJLG Industries, Inc.1 JLG DriveMcConnellsburg PA. 17233-9533USAPhone: (717) 485-5161Fax: (717) 485-6417JLG Ind

Strany 80 - JLG Worldwide Locations

SECTION 1 - SPECIFICATIONS3120855 – JLG Sizzor – 1-3Ground ClearanceWith Platform LoweredAll Models - 8.0 cmWith Platform Elevated(Pothole Protection